Nuclear Magnetic Resonance Spectroscopy Laboratory (NMRL)
Nuclear Magnetic Resonance (NMR) is a spectroscopic examination that gives information about the structures and chemical properties of organic molecules. By using NMR, information about the structure, bonding properties, and molecular formula of solid or liquid samples can be obtained. There are two NMR devices used for this purpose. These are Bruker Avance's 300 MHz (7 Tesla) solid and liquid NMR spectrometers. | |
Flyer |
Instruments(This Lab)
Contact
mlabnmrlmetu [dot] edu [dot] tr
Laboratory email address is our preferred way of communication. Incoming calls during analysis cause difficulties during analysis. Please ask your questions via email.
Staff
Uzman | e-posta |
---|---|
Lecturer Ceren Nur Biler |
mlabnmrlmetu [dot] edu [dot] tr |
Güler Bayraklı Çelik |
mlabnmrlmetu [dot] edu [dot] tr |
Lecturer Merve Çerçi (SNMR) |
mlabnmrlmetu [dot] edu [dot] tr |
Service Fees
We do not have a decision rule and no declaration of conformity is given.
Depending on the Applicant Institution Following Discount Rates can be Applied. |
|
METU | %65 |
Universities other than METU (Public, Foundation) | %40 |
METU Technopark | %30 |
Public institutions and organizations | %20 |
Technoparks at Other Universities | %15 |
Public University and private sector cooperation (If the application is made through the University Channel) |
%20 |
|
|
METU Central Laboratory reserves the right to change the |
|
20% VAT is not included in the Analysis Fees. There is no university or institution discount in the analysis fee for individual applications made by |
|
For test requests, multiple samples and research test requests that are not specified in the test list, |
METU Central Laboratory reserves the right to change the Fees and/or Remuneration System without prior notice.
Method/Analysis Name | Service Description | Fee | Analysis Request Form |
---|---|---|---|
Solid NMR 13CPMAS | 4 Hours | 1250₺ | Out of order |
8 Hours | 1520₺ | ||
16 Hours | 1920₺ | ||
27 Hours | 2180₺ | ||
When the sample contaminates the sample chamber | 5500₺ | ||
Solid NMR 29SiMAS, 27AlMAS | 4 Hours | 1400₺ | Out of order |
8 Hours | 1820₺ | ||
16 Hours | 2090₺ | ||
27 Hours | 2600₺ | ||
When the sample contaminates the sample chamber | 5500₺ | ||
Liguid NMR | 1H (Proton) Spectrum | 430₺/Sample | Form |
13C (Coupled/Decoupled) Spectrum 0-1 Hours | 730₺/Sample | ||
13C (Coupled/Decoupled) Spectrum 1-3 Hours | 860₺/Sample | ||
13C (Coupled/Decoupled) Spectrum 3-7 Hours | 1000₺/Sample | ||
13C (Coupled/Decoupled) Spectrum 7-19 Hours | 1300₺/Sample | ||
31P Spectrum | 940/Sample | ||
19F Spectrum | 940₺/Sample | ||
Solvents |
Acetone-D6 | The responsibility for procuring the requisite chemical solvent lies with the interested party. | |
Benzene-D6 | The responsibility for procuring the requisite chemical solvent lies with the interested party. | ||
Chloroform-D1 | 85₺ | ||
Deuterium Oxide | 85₺ | ||
Dimethyl sulfoxide-D6 | 85₺ | ||
Pyridine-D5 | The responsibility for procuring the requisite chemical solvent lies with the interested party. | ||
Toluene-D8 | The responsibility for procuring the requisite chemical solvent lies with the interested party. |
Nuclear Magnetic Resonance (NMR) is a spectroscopic examination that gives information about the structures and chemical properties of organic molecules. By using NMR, information about the structure, bonding properties, and molecular formula of solid or liquid samples can be obtained. There are two NMR devices used for this purpose. These are Bruker Avance's 300 MHz (7 Tesla) solid and liquid NMR spectrometers. | |
Flyer |
Contact
mlabnmrlmetu [dot] edu [dot] tr
Laboratory email address is our preferred way of communication. Incoming calls during analysis cause difficulties during analysis. Please ask your questions via email.
Staff
Uzman | e-posta |
---|---|
Lecturer Ceren Nur Biler |
mlabnmrlmetu [dot] edu [dot] tr |
Güler Bayraklı Çelik |
mlabnmrlmetu [dot] edu [dot] tr |
Lecturer Merve Çerçi (SNMR) |
mlabnmrlmetu [dot] edu [dot] tr |
Service Fees
We do not have a decision rule and no declaration of conformity is given.
Depending on the Applicant Institution Following Discount Rates can be Applied. |
|
METU | %65 |
Universities other than METU (Public, Foundation) | %40 |
METU Technopark | %30 |
Public institutions and organizations | %20 |
Technoparks at Other Universities | %15 |
Public University and private sector cooperation (If the application is made through the University Channel) |
%20 |
|
|
METU Central Laboratory reserves the right to change the |
|
20% VAT is not included in the Analysis Fees. There is no university or institution discount in the analysis fee for individual applications made by |
|
For test requests, multiple samples and research test requests that are not specified in the test list, |
METU Central Laboratory reserves the right to change the Fees and/or Remuneration System without prior notice.
Method/Analysis Name | Service Description | Fee | Analysis Request Form |
---|---|---|---|
Solid NMR 13CPMAS | 4 Hours | 1250₺ | Out of order |
8 Hours | 1520₺ | ||
16 Hours | 1920₺ | ||
27 Hours | 2180₺ | ||
When the sample contaminates the sample chamber | 5500₺ | ||
Solid NMR 29SiMAS, 27AlMAS | 4 Hours | 1400₺ | Out of order |
8 Hours | 1820₺ | ||
16 Hours | 2090₺ | ||
27 Hours | 2600₺ | ||
When the sample contaminates the sample chamber | 5500₺ | ||
Liguid NMR | 1H (Proton) Spectrum | 430₺/Sample | Form |
13C (Coupled/Decoupled) Spectrum 0-1 Hours | 730₺/Sample | ||
13C (Coupled/Decoupled) Spectrum 1-3 Hours | 860₺/Sample | ||
13C (Coupled/Decoupled) Spectrum 3-7 Hours | 1000₺/Sample | ||
13C (Coupled/Decoupled) Spectrum 7-19 Hours | 1300₺/Sample | ||
31P Spectrum | 940/Sample | ||
19F Spectrum | 940₺/Sample | ||
Solvents |
Acetone-D6 | The responsibility for procuring the requisite chemical solvent lies with the interested party. | |
Benzene-D6 | The responsibility for procuring the requisite chemical solvent lies with the interested party. | ||
Chloroform-D1 | 85₺ | ||
Deuterium Oxide | 85₺ | ||
Dimethyl sulfoxide-D6 | 85₺ | ||
Pyridine-D5 | The responsibility for procuring the requisite chemical solvent lies with the interested party. | ||
Toluene-D8 | The responsibility for procuring the requisite chemical solvent lies with the interested party. |