Instrument: Hetoholten model safe 2010-1.2 class II safety cabinet

Desktop, closed-safe work environment

Specifications

  • The windshield is electric, inclined, and guillotine type and can be completely closed when the UV lamp is turned on.
  • The working surface consists of 4 pieces of autoclavable steel.
  • The device has two HEPA filters, one main and one exhaust. 75% of the air is circulated to the work surface, and 25% is given to the room through the exhaust HEPA filter.
  • HEPA filters can hold particles of 0.3 microns and larger with an efficiency of 99.99%.
  • The device has microprocessor control, LCD and also has an audible and light alarm system.
  • The automatic start of the clock, reduced speed, UV timer, filter change time, or any malfunction can be followed on the digital screen.
  • Air ducts at risk of contamination are surrounded by negative pressure.

Applications

A safe and closed environment on the desktop, used in work that requires the protection of the worker, the product, and the environment.

Molecular Biology and Biotechnology R&D Center

Tissue Culture Laboratory (DKL)

Multiple Gas Oven
Safety Cabinet


Laboratories

Molecular Biology and Biotechnology R&D Center

Tissue Culture Laboratory (DKL)

Multiple Gas Oven
Safety Cabinet


Laboratories

Share
Tweet
  • English
  • Türkçe
Listen

Instrument: Hetoholten model safe 2010-1.2 class II safety cabinet

Desktop, closed-safe work environment

Specifications

  • The windshield is electric, inclined, and guillotine type and can be completely closed when the UV lamp is turned on.
  • The working surface consists of 4 pieces of autoclavable steel.
  • The device has two HEPA filters, one main and one exhaust. 75% of the air is circulated to the work surface, and 25% is given to the room through the exhaust HEPA filter.
  • HEPA filters can hold particles of 0.3 microns and larger with an efficiency of 99.99%.
  • The device has microprocessor control, LCD and also has an audible and light alarm system.
  • The automatic start of the clock, reduced speed, UV timer, filter change time, or any malfunction can be followed on the digital screen.
  • Air ducts at risk of contamination are surrounded by negative pressure.

Applications

A safe and closed environment on the desktop, used in work that requires the protection of the worker, the product, and the environment.