Goniometer (Optical Contact Angle/Surface Tension Measurement Device) (TAYG)

Share
Tweet
Listen
  • English
  • Türkçe

Instrument: Attension Theta

The goniometer is used to determine the properties of liquids and solids in various industries and research areas.

Specifications

The goniometer records the drop images and automatically analyzes the drop shape over time. The droplet shape is a function of the surface tension of the liquid, the density difference between the liquid and the surrounding medium. On solid surfaces, the drop shape and contact angle depend on the free surface energy of the solid. Measurements of contact angle, surface tension, interfacial tension and surface free energy; wettability, liquid absorption, liquid retention, liquid diffusion, surface cleanliness, surface heterogeneity, emulsion stability etc. Provides information about material properties such as

Applicable Drip Profiles

Stationary (sessile), hanging (pendant), tilting drop, fixed bubble, meniscus drop types and static contact angles "advancing contact angle" advancing to the front of the liquid and "receding" contact angle advancing to the back of the liquid " is determined in two ways.

Measurement Type

The following measurements are possible with the Theta device:

For solid samples:

  • Static contact angle
  • Free surface energy

For liquid samples:

  • Surface tension
    • Interface voltage

Sample Requirements

The method can be applied to solid and liquid samples. Dry and surface of solid samples are free of dust, dirt, etc. must be free from contamination. Samples with deep pits and rough structures are not measured. If only the contact angle measurement is required for solid samples, a total area of ​​at least 4 cm2, if contact angle and free surface energy measurement is desired, a sample with a total area of ​​at least 10 cm2 should be provided.

Before the application, it is recommended to have a preliminary interview with the responsible specialist about the status of the device and the experiment to be performed.

R&D Training and Measurement Center

Surface and Pore Characterization Laboratory (YGL)

Goniometer (Optical Contact Angle/Surface Tension Measurement Device) (TAYG)
Helium Pycnometer
Mercury Porosimetry
Surface Characterization Device I (AUTOSORB-1C/MS)
Surface Characterization Device II (AUTOSORB-6B)


Laboratories

R&D Training and Measurement Center

Surface and Pore Characterization Laboratory (YGL)

Goniometer (Optical Contact Angle/Surface Tension Measurement Device) (TAYG)
Helium Pycnometer
Mercury Porosimetry
Surface Characterization Device I (AUTOSORB-1C/MS)
Surface Characterization Device II (AUTOSORB-6B)


Laboratories

Share
Tweet
  • English
  • Türkçe
Listen

Instrument: Attension Theta

The goniometer is used to determine the properties of liquids and solids in various industries and research areas.

Specifications

The goniometer records the drop images and automatically analyzes the drop shape over time. The droplet shape is a function of the surface tension of the liquid, the density difference between the liquid and the surrounding medium. On solid surfaces, the drop shape and contact angle depend on the free surface energy of the solid. Measurements of contact angle, surface tension, interfacial tension and surface free energy; wettability, liquid absorption, liquid retention, liquid diffusion, surface cleanliness, surface heterogeneity, emulsion stability etc. Provides information about material properties such as

Applicable Drip Profiles

Stationary (sessile), hanging (pendant), tilting drop, fixed bubble, meniscus drop types and static contact angles "advancing contact angle" advancing to the front of the liquid and "receding" contact angle advancing to the back of the liquid " is determined in two ways.

Measurement Type

The following measurements are possible with the Theta device:

For solid samples:

  • Static contact angle
  • Free surface energy

For liquid samples:

  • Surface tension
    • Interface voltage

Sample Requirements

The method can be applied to solid and liquid samples. Dry and surface of solid samples are free of dust, dirt, etc. must be free from contamination. Samples with deep pits and rough structures are not measured. If only the contact angle measurement is required for solid samples, a total area of ​​at least 4 cm2, if contact angle and free surface energy measurement is desired, a sample with a total area of ​​at least 10 cm2 should be provided.

Before the application, it is recommended to have a preliminary interview with the responsible specialist about the status of the device and the experiment to be performed.