X-Ray Diffraction Laboratory (XRDL)
![]() |
By detecting the X-rays refracted from the materials, the structure of the target crystal can be understood. The X-ray diffraction device used in the analysis can be operated in either focal or parallel beam geometry. In addition, measurements can be taken at the swept angle position in thin film and polycrystalline samples. |
| Flyer |
Instruments(This Lab)
Contact
mlabxrdl
metu [dot] edu [dot] tr
Laboratory email address is our preferred way of communication. Incoming calls during analysis cause difficulties during analysis. Please ask your questions via email.
Staff
| Uzman | e-posta |
|---|---|
|
Lecturer PhD. Ali Güzel Laboratuvar Sorumlusu |
mlabxrdl |
| Lecturer Pelin Paşabeyoğlu |
mlabxrdl |
Service Fees
We do not have a decision rule and no declaration of conformity is given.
| Depending on the Applicant Institution Following Discount Rates can be Applied. |
|
| METU | %65 |
| Universities other than METU (Public, Foundation) | %40 |
| METU Technopark | %30 |
| Public institutions and organizations | %20 |
| Technoparks at Other Universities | %15 |
| Public University and private sector cooperation (If the application is made through the University Channel) |
%20 |
|
|
|
|
METU Central Laboratory reserves the right to change the |
|
|
20% VAT is not included in the Analysis Fees. There is no university or institution discount in the analysis fee for individual applications made by |
|
|
For test requests, multiple samples and research test requests that are not specified in the test list, |
|
METU Central Laboratory reserves the right to change the Fees and/or Remuneration System without prior notice.
| Method/Analysis Name | Service Description | Fee | Analysis Request Form |
|---|---|---|---|
| XRD | Powder Diffraction Pattern Standard Shot | 1500₺/Numune | Form |
|
Thin Film1 Diffraction Pattern Capture (Up to 1 Hour) |
1500₺/Numune |
||
|
For every additional hour |
450₺ |
||
|
Qualitative and Quantitative Analysis2 |
1500₺/Sample |
||
|
1Device adjustments (approximately 15min/sample) and time taken for trial measurements will be charged for thin film measurements. 2Within the scope of this analysis, the suitability of the methods to be applied will be determined based on the technical discussions to be held with the client and the laboratory. The scope and details of the analyses will be finalized, after which the process will be planned.The price has been determined based on the current list price of 1,500 TL per sample (excluding any discounts). |
|||
Instruments(This Lab)
![]() |
By detecting the X-rays refracted from the materials, the structure of the target crystal can be understood. The X-ray diffraction device used in the analysis can be operated in either focal or parallel beam geometry. In addition, measurements can be taken at the swept angle position in thin film and polycrystalline samples. |
| Flyer |
Contact
mlabxrdl
metu [dot] edu [dot] tr
Laboratory email address is our preferred way of communication. Incoming calls during analysis cause difficulties during analysis. Please ask your questions via email.
Staff
| Uzman | e-posta |
|---|---|
|
Lecturer PhD. Ali Güzel Laboratuvar Sorumlusu |
mlabxrdl |
| Lecturer Pelin Paşabeyoğlu |
mlabxrdl |
Service Fees
We do not have a decision rule and no declaration of conformity is given.
| Depending on the Applicant Institution Following Discount Rates can be Applied. |
|
| METU | %65 |
| Universities other than METU (Public, Foundation) | %40 |
| METU Technopark | %30 |
| Public institutions and organizations | %20 |
| Technoparks at Other Universities | %15 |
| Public University and private sector cooperation (If the application is made through the University Channel) |
%20 |
|
|
|
|
METU Central Laboratory reserves the right to change the |
|
|
20% VAT is not included in the Analysis Fees. There is no university or institution discount in the analysis fee for individual applications made by |
|
|
For test requests, multiple samples and research test requests that are not specified in the test list, |
|
METU Central Laboratory reserves the right to change the Fees and/or Remuneration System without prior notice.
| Method/Analysis Name | Service Description | Fee | Analysis Request Form |
|---|---|---|---|
| XRD | Powder Diffraction Pattern Standard Shot | 1500₺/Numune | Form |
|
Thin Film1 Diffraction Pattern Capture (Up to 1 Hour) |
1500₺/Numune |
||
|
For every additional hour |
450₺ |
||
|
Qualitative and Quantitative Analysis2 |
1500₺/Sample |
||
|
1Device adjustments (approximately 15min/sample) and time taken for trial measurements will be charged for thin film measurements. 2Within the scope of this analysis, the suitability of the methods to be applied will be determined based on the technical discussions to be held with the client and the laboratory. The scope and details of the analyses will be finalized, after which the process will be planned.The price has been determined based on the current list price of 1,500 TL per sample (excluding any discounts). |
|||
