Thermogravimetric Analysis and Differential Thermal Analysis System (TGDT)

Share
Tweet
Listen
  • English
  • Türkçe

Instrument: Setaram Labsys Thermogravimetry Analysis and Differential Thermal Analysis System (TG/DT)

TGA/DTA is a simultaneous technique. The weight change of the sample and the temperature difference between it and the reference are measured using a controlled temperature program.

Specifications

  • Temperature range: 25 ºC - 1200 ºC
  • Weight accuracy: 0.4 µg
  • Measuring range: ±200 mg
  • Tracking rate: 0.01 - 50 ºC / min.

Sample Requirements

  • Solid materials (preferably in powder form).
  • Sample weight: approx. 100mg
  • Sample size: diameter:4 mm; height: not more than 4mm.

Applications

  • Glass transition temperature
  • Melting temperature
  • Phase change
  • Mass loss

R&D Training and Measurement Center

Thermal Analysis Laboratory (TAL)

Differential Scanning Calorimetry (DSC)
Dynamic Mechanical Analyzer (DMA)
Simultaneous DSC/TGA (SDT)
Thermal Conductivity Analyzer (TİC)
Thermogravimetric Analysis and Differential Thermal Analysis System (TGDT)
Thermogravimetric Analysis and Infrared Spectrometer (TGFT)
Thermogravimetric Analyzer


Laboratories

R&D Training and Measurement Center

Thermal Analysis Laboratory (TAL)

Differential Scanning Calorimetry (DSC)
Dynamic Mechanical Analyzer (DMA)
Simultaneous DSC/TGA (SDT)
Thermal Conductivity Analyzer (TİC)
Thermogravimetric Analysis and Differential Thermal Analysis System (TGDT)
Thermogravimetric Analysis and Infrared Spectrometer (TGFT)
Thermogravimetric Analyzer


Laboratories

Share
Tweet
  • English
  • Türkçe
Listen

Instrument: Setaram Labsys Thermogravimetry Analysis and Differential Thermal Analysis System (TG/DT)

TGA/DTA is a simultaneous technique. The weight change of the sample and the temperature difference between it and the reference are measured using a controlled temperature program.

Specifications

  • Temperature range: 25 ºC - 1200 ºC
  • Weight accuracy: 0.4 µg
  • Measuring range: ±200 mg
  • Tracking rate: 0.01 - 50 ºC / min.

Sample Requirements

  • Solid materials (preferably in powder form).
  • Sample weight: approx. 100mg
  • Sample size: diameter:4 mm; height: not more than 4mm.

Applications

  • Glass transition temperature
  • Melting temperature
  • Phase change
  • Mass loss

Merkezi Laboratuvar ARGE Eğitim Ölçme Merkezi Üniversiteler Mahallesi, Dumlupınar Bulvarı No:1, 06800 Çankaya/Ankara © ORTA DOĞU TEKNİK ÜNİVERSİTESİ ANKARA KAMPUSU