Growth Chamber
Instrument: Fitotron SGC1700
FITOTRON series grow chambers provide precision and reliability in temperature, humidity and lighting control. High-quality building material guarantees maximum durability and reliability;
- Zinc protected finish with baked acrylic lacquer.
- Highly reflective and emissive white polished stainless steel growth cabinet.
- Separated lighting from the grow cabinet for safety and efficiency.
- Wheel mounted for mobility.
- Safety thermostat protector as standard.
- Observation window and cable entry port.
FITOTRON series plant growth chambers are equipped with highly efficient, high-frequency fluorescent lamps. The possibility for users to adjust the light output to the actual light level required is standard. The light level can be preselected in the periodic control system or programmed to simulate morning dimness.
Displayed test parameters
- Digital display of temperature and humidity,
- Light period control
- Adjusted light level
Specifications
Physical
- Capacity:1658 liters
- Inner Dimension (WxDxH) mm:1400 x 800 x 148
- External Dimension (WxDxH) mm:2285 x 1000 x 2150
- Magnification Area: 1.12m2
- Magnification height: 1.40m
- Air velocity (nominal), vertical:0.2ms
Performance
- Temperature Range (light off):0°C to 40°C
- Temperature Range (light on):+7°C to +40°C
- Temperature Deviation: ±0.2°C
- Difference (single surface, light on):±1.0°C
Humidity Range
- 25% to 88% r.h. @ +40°C
- 42% to 95% r.h. @ +20°C
- 50% to 95% r.h. @ +10°C
- Humidity Deviation:4% @ min % r.h. 7% @ max % r.h.
- Light Level, max @ 300mm from surface, +25oC light box temperature. (nominal):900 µmol.m-2s-179,000 lux 200 Wm-2
Facilities
- Controllers, temperature/humidity:3 term, p.i.d./diurnal cycling
- Sensors, temperature/humidity: PRT 100W @ 0oC/wet-dry bulb
- Illumination, main: 20 x 50 W fluorescent/dimmable
- Lighting, additional: 8 x 60W tungsten
- Lighting period sequencer: Independent of main and auxiliary lights
Operational
- Power supply range: 380-440V, 3ph+n, 50Hz
- Pure water requirement: 3lsa-1
- Pollution output: 60dbA
Contact
merlabmetu [dot] edu [dot] tr
Service Fees
We do not have a decision rule and no declaration of conformity is given.
Depending on the Applicant Institution Following Discount Rates can be Applied. |
|
METU | %65 |
Universities other than METU (Public, Foundation) | %40 |
METU Technopark | %30 |
Public institutions and organizations | %20 |
Technoparks at Other Universities | %15 |
Public University and private sector cooperation (If the application is made through the University Channel) |
%20 |
|
|
METU Central Laboratory reserves the right to change the |
|
20% VAT is not included in the Analysis Fees. There is no university or institution discount in the analysis fee for individual applications made by |
|
For test requests, multiple samples and research test requests that are not specified in the test list, |
METU Central Laboratory reserves the right to change the Fees and/or Remuneration System without prior notice.
Method/Analysis Name | Service Description | Fee | Analysis Request Form |
---|---|---|---|
Usage | 1200₺/Day | contact via e-mail |
Instrument: Fitotron SGC1700
FITOTRON series grow chambers provide precision and reliability in temperature, humidity and lighting control. High-quality building material guarantees maximum durability and reliability;
- Zinc protected finish with baked acrylic lacquer.
- Highly reflective and emissive white polished stainless steel growth cabinet.
- Separated lighting from the grow cabinet for safety and efficiency.
- Wheel mounted for mobility.
- Safety thermostat protector as standard.
- Observation window and cable entry port.
FITOTRON series plant growth chambers are equipped with highly efficient, high-frequency fluorescent lamps. The possibility for users to adjust the light output to the actual light level required is standard. The light level can be preselected in the periodic control system or programmed to simulate morning dimness.
Displayed test parameters
- Digital display of temperature and humidity,
- Light period control
- Adjusted light level
Specifications
Physical
- Capacity:1658 liters
- Inner Dimension (WxDxH) mm:1400 x 800 x 148
- External Dimension (WxDxH) mm:2285 x 1000 x 2150
- Magnification Area: 1.12m2
- Magnification height: 1.40m
- Air velocity (nominal), vertical:0.2ms
Performance
- Temperature Range (light off):0°C to 40°C
- Temperature Range (light on):+7°C to +40°C
- Temperature Deviation: ±0.2°C
- Difference (single surface, light on):±1.0°C
Humidity Range
- 25% to 88% r.h. @ +40°C
- 42% to 95% r.h. @ +20°C
- 50% to 95% r.h. @ +10°C
- Humidity Deviation:4% @ min % r.h. 7% @ max % r.h.
- Light Level, max @ 300mm from surface, +25oC light box temperature. (nominal):900 µmol.m-2s-179,000 lux 200 Wm-2
Facilities
- Controllers, temperature/humidity:3 term, p.i.d./diurnal cycling
- Sensors, temperature/humidity: PRT 100W @ 0oC/wet-dry bulb
- Illumination, main: 20 x 50 W fluorescent/dimmable
- Lighting, additional: 8 x 60W tungsten
- Lighting period sequencer: Independent of main and auxiliary lights
Operational
- Power supply range: 380-440V, 3ph+n, 50Hz
- Pure water requirement: 3lsa-1
- Pollution output: 60dbA
Contact
merlabmetu [dot] edu [dot] tr
Service Fees
We do not have a decision rule and no declaration of conformity is given.
Depending on the Applicant Institution Following Discount Rates can be Applied. |
|
METU | %65 |
Universities other than METU (Public, Foundation) | %40 |
METU Technopark | %30 |
Public institutions and organizations | %20 |
Technoparks at Other Universities | %15 |
Public University and private sector cooperation (If the application is made through the University Channel) |
%20 |
|
|
METU Central Laboratory reserves the right to change the |
|
20% VAT is not included in the Analysis Fees. There is no university or institution discount in the analysis fee for individual applications made by |
|
For test requests, multiple samples and research test requests that are not specified in the test list, |
METU Central Laboratory reserves the right to change the Fees and/or Remuneration System without prior notice.
Method/Analysis Name | Service Description | Fee | Analysis Request Form |
---|---|---|---|
Usage | 1200₺/Day | contact via e-mail |