Stable Isotope Ratio Mass Spectrometry Laboratory (DİL)
The stable isotope compositions of waters are used as tracking parameters in the investigation of issues such as the origins of the waters, the physico-chemical processes they undergo underground, and the regional flow directions. In this laboratory, δ18O/16O and δ2H/1H isotope ratios are determined in water. Our laboratory participated in the proficiency test on Determination of Stable Isotope Ratio in Waters organized by IAEA in 2011 and received a valid score. | |
Leaflet |
Instruments(This Lab)
Contact
mlabdilmetu [dot] edu [dot] tr
Laboratory email address is our preferred way of communication. Incoming calls during analysis cause difficulties during analysis. Please ask your questions via email.
Staff
Uzman | e-posta |
---|---|
Lecturer PhD. Selin Süer Laboratuvar Sorumlusu |
mlabdilmetu [dot] edu [dot] tr |
Lecturer Elif Kanbertay Canlı |
mlabdilmetu [dot] edu [dot] tr |
Çiğdem Sevin |
mlabdilmetu [dot] edu [dot] tr |
Service Fees
We do not have a decision rule and no declaration of conformity is given.
Depending on the Applicant Institution Following Discount Rates can be Applied. |
|
METU | %65 |
Universities other than METU (Public, Foundation) | %40 |
METU Technopark | %30 |
Public institutions and organizations | %20 |
Technoparks at Other Universities | %15 |
Public University and private sector cooperation (If the application is made through the University Channel) |
%20 |
|
|
METU Central Laboratory reserves the right to change the |
|
20% VAT is not included in the Analysis Fees. There is no university or institution discount in the analysis fee for individual applications made by |
|
For test requests, multiple samples and research test requests that are not specified in the test list, |
METU Central Laboratory reserves the right to change the Fees and/or Remuneration System without prior notice.
Method/Analysis Name | Description | Price | Analysis Request Form |
---|---|---|---|
Water Samples | 18O/16O quantification | 700₺/Sample | Form |
2H/1H quantification | 700₺/Sample | ||
13C/12C - DIC quantification | 800₺/Sample | ||
Solid Samples | 13C/12C, 18O/16O - carbonate quantification | 800₺/Sample | Form |
* Accredited Analyses
Please consult the laboratory before sending applications and samples, there is already a sample analysis queue.
Instruments(This Lab)
The stable isotope compositions of waters are used as tracking parameters in the investigation of issues such as the origins of the waters, the physico-chemical processes they undergo underground, and the regional flow directions. In this laboratory, δ18O/16O and δ2H/1H isotope ratios are determined in water. Our laboratory participated in the proficiency test on Determination of Stable Isotope Ratio in Waters organized by IAEA in 2011 and received a valid score. | |
Leaflet |
Contact
mlabdilmetu [dot] edu [dot] tr
Laboratory email address is our preferred way of communication. Incoming calls during analysis cause difficulties during analysis. Please ask your questions via email.
Staff
Uzman | e-posta |
---|---|
Lecturer PhD. Selin Süer Laboratuvar Sorumlusu |
mlabdilmetu [dot] edu [dot] tr |
Lecturer Elif Kanbertay Canlı |
mlabdilmetu [dot] edu [dot] tr |
Çiğdem Sevin |
mlabdilmetu [dot] edu [dot] tr |
Service Fees
We do not have a decision rule and no declaration of conformity is given.
Depending on the Applicant Institution Following Discount Rates can be Applied. |
|
METU | %65 |
Universities other than METU (Public, Foundation) | %40 |
METU Technopark | %30 |
Public institutions and organizations | %20 |
Technoparks at Other Universities | %15 |
Public University and private sector cooperation (If the application is made through the University Channel) |
%20 |
|
|
METU Central Laboratory reserves the right to change the |
|
20% VAT is not included in the Analysis Fees. There is no university or institution discount in the analysis fee for individual applications made by |
|
For test requests, multiple samples and research test requests that are not specified in the test list, |
METU Central Laboratory reserves the right to change the Fees and/or Remuneration System without prior notice.
Method/Analysis Name | Description | Price | Analysis Request Form |
---|---|---|---|
Water Samples | 18O/16O quantification | 700₺/Sample | Form |
2H/1H quantification | 700₺/Sample | ||
13C/12C - DIC quantification | 800₺/Sample | ||
Solid Samples | 13C/12C, 18O/16O - carbonate quantification | 800₺/Sample | Form |
* Accredited Analyses
Please consult the laboratory before sending applications and samples, there is already a sample analysis queue.